{"id":6184,"date":"2026-04-20T18:17:41","date_gmt":"2026-04-20T16:17:41","guid":{"rendered":"https:\/\/control-protection.be\/?page_id=6184"},"modified":"2026-04-21T09:22:08","modified_gmt":"2026-04-21T07:22:08","slug":"solutions-de-test-pour-decharges-partielles","status":"publish","type":"page","link":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/","title":{"rendered":"Solutions de test pour d\u00e9charges partielles"},"content":{"rendered":"<div class=\"column\">\n\t<div class=\"rw-boostu-wrapper rw-whitespace\"><\/div><div class=\"rw-boostu-wrapper rw-whitespace\"><\/div><div class=\"rw-boostu-wrapper rw-cta cta-bg-color with-image\">\n    <div class=\"wpbf-container\">\n        <div class=\"cta-text\">\n            <h2>Mesure et surveillance des d\u00e9charges partielles<\/h2>\n            <div><p>Les d\u00e9charges partielles (DP) constituent l&rsquo;un des premiers signes de dysfonctionnement dans les syst\u00e8mes \u00e9lectriques. En les d\u00e9tectant \u00e0 un stade pr\u00e9coce, vous \u00e9vitez les dommages, les temps d&rsquo;arr\u00eat et les r\u00e9parations co\u00fbteuses.<\/p>\n<p>Control &amp; Protection vous aide \u00e0 identifier ces probl\u00e8mes d\u00e8s leur apparition. Nous utilisons des solutions avanc\u00e9es de test et de surveillance des d\u00e9charges partielles afin de vous fournir des informations claires et fiables sur l&rsquo;\u00e9tat de vos \u00e9quipements.<\/p>\n<\/div>\n            <p><a class=\"arrow-btn\" href=\"#producten\" target=\"_self\">Vous souhaitez voir les produits ?<\/a><\/p>\n        <\/div>\n                    <img decoding=\"async\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/DCX_CLP_PartialDisch_IMAGE-1-small.png\" alt=\"DCX_CLP_PartialDisch_IMAGE-1-small\">\n            <\/div>\n<\/div><div class=\"rw-boostu-wrapper rw-text align-left \">\n    <div class=\"wpbf-container\">\n        <div class=\"text-wrapper\">\n            <h3>Pourquoi les d\u00e9charges partielles sont-elles importantes ?<\/h3>\n<p>Les d\u00e9charges partielles surviennent lorsque l&rsquo;isolation commence \u00e0 se d\u00e9t\u00e9riorer. Elles apparaissent souvent bien avant qu&rsquo;une panne ne se produise.<\/p>\n<p>Sans tests appropri\u00e9s, ces probl\u00e8mes restent cach\u00e9s jusqu&rsquo;\u00e0 ce qu&rsquo;il soit trop tard.<\/p>\n<p>Gr\u00e2ce \u00e0 des mesures ad\u00e9quates, vous pouvez :<\/p>\n<ul>\n<li>D\u00e9tecter pr\u00e9cocement les d\u00e9fauts d&rsquo;isolation<\/li>\n<li>Localiser les points faibles de votre installation<\/li>\n<li>Planifier la maintenance au lieu de r\u00e9agir aux pannes<\/li>\n<li>Prolonger la dur\u00e9e de vie de vos \u00e9quipements<\/li>\n<\/ul>\n<p>Nos solutions de d\u00e9tection des d\u00e9charges partielles permettent d&rsquo;\u00e9valuer un large \u00e9ventail d&rsquo;\u00e9quipements haute tension, tels que les machines tournantes, les transformateurs, les c\u00e2bles d&rsquo;alimentation, les appareillages de commutation et les travers\u00e9es.<\/p>\n        <\/div>\n    <\/div>\n<\/div><div class=\"rw-boostu-wrapper rw-whitespace\"><\/div><div class=\"rw-boostu-wrapper rw-text align-left \">\n    <div class=\"wpbf-container\">\n        <div class=\"text-wrapper\">\n            <h2 id=\"producten\">Mesure avanc\u00e9e des d\u00e9charges partielles avec Megger<\/h2>\n<p>Nous utilisons la technologie \u00e9prouv\u00e9e de <a title=\"En savoir plus sur Megger\" href=\"https:\/\/control-protection.be\/fr\/marques-fr\/megger-fr\/\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">Megger<\/span><\/a>. Leurs \u00e9quipements sont con\u00e7us pour d\u00e9tecter, mesurer et analyser avec pr\u00e9cision les d\u00e9charges partielles. Vous obtenez ainsi des donn\u00e9es fiables sur lesquelles vous pouvez vous appuyer.<\/p>\n<p>Nos tests de d\u00e9charges partielles s&rsquo;inscrivent \u00e9galement dans le cadre des essais de r\u00e9ception en usine (FAT) et des essais de r\u00e9ception sur site (SAT). Vous b\u00e9n\u00e9ficiez ainsi d&rsquo;une performance v\u00e9rifi\u00e9e et d&rsquo;une tranquillit\u00e9 d&rsquo;esprit avant la mise en service des syst\u00e8mes.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table width=\"1500\">\n<tbody>\n<tr>\n<td width=\"500\">\n<div style=\"text-align: center;\">\n<p><a title=\"En savoir plus sur ICMneo partial discharge measuring device\" href=\"https:\/\/www.megger.com\/en\/products\/icmneo\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6659\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMneo_PRODWEB_004.png-300x300.webp\" alt=\"ICMneo partial discharge measuring device\" width=\"300\" height=\"300\" srcset=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMneo_PRODWEB_004.png-300x300.webp 300w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMneo_PRODWEB_004.png-150x150.webp 150w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMneo_PRODWEB_004.png.webp 680w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\n<\/a><\/p>\n<\/div>\n<h3>ICMneo &#8211; Appareil num\u00e9rique de test et de mesure des d\u00e9charges partielles<\/h3>\n<p>Appareil de mesure num\u00e9rique multicanaux compact destin\u00e9 \u00e0 l&rsquo;\u00e9valuation de l&rsquo;isolation moyenne et haute tension, alliant fiabilit\u00e9, pr\u00e9cision et flexibilit\u00e9. Compatible avec tous les accessoires de mesure des d\u00e9charges partielles de Megger. Facile \u00e0 utiliser, autonome et hautement modulaire.<\/p>\n<p><a title=\"En savoir plus sur ICMneo partial discharge measuring device\" href=\"https:\/\/www.megger.com\/en\/products\/icmneo\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">En savoir plus<\/span><\/a><\/td>\n<td width=\"500\">\n<div style=\"text-align: center;\">\n<p><a title=\"En savoir plus sur ICMobserver partial discharge monitoring system\" href=\"https:\/\/www.megger.com\/en\/products\/icmobserver-pd-monitoring-system\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6656\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMObserver_PRODWEB_004.png-300x300.webp\" alt=\"ICMobserver partial discharge monitoring system\" width=\"300\" height=\"300\" srcset=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMObserver_PRODWEB_004.png-300x300.webp 300w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMObserver_PRODWEB_004.png-150x150.webp 150w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMObserver_PRODWEB_004.png.webp 680w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\n<\/a><\/p>\n<\/div>\n<h3>ICMobserver \u2013 Syst\u00e8me de surveillance des d\u00e9charges partielles<\/h3>\n<p>Solution de pointe pour la surveillance des d\u00e9charges partielles<br \/>\nL&rsquo;ICMobserver est un syst\u00e8me de surveillance des d\u00e9charges partielles polyvalent qui r\u00e9unit en un seul instrument tout le n\u00e9cessaire pour la surveillance des d\u00e9charges partielles et l&rsquo;\u00e9valuation approfondie de l&rsquo;\u00e9tat des installations.<\/p>\n<p><a title=\"En savoir plus sur ICMobserver partial discharge monitoring system\" href=\"https:\/\/www.megger.com\/en\/products\/icmobserver-pd-monitoring-system\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">En savoir plus<\/span><\/a><\/td>\n<td width=\"500\">\n<div style=\"text-align: center;\">\n<p><a title=\"En savoir plus sur ICMflex partial discharge detector\" href=\"https:\/\/www.megger.com\/en\/products\/icmflex-partial-discharge-detector-partial-discharge-fault-locator-and-loss-factor\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6650\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMflex_WEBI_002.png-300x300.webp\" alt=\"ICMflex partial discharge detector\" width=\"300\" height=\"300\" srcset=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMflex_WEBI_002.png-300x300.webp 300w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMflex_WEBI_002.png-150x150.webp 150w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMflex_WEBI_002.png.webp 680w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\n<\/a><\/p>\n<\/div>\n<h3>ICMflex \u2013 D\u00e9tecteur de d\u00e9charges partielles, localisateur de d\u00e9fauts de d\u00e9charges partielles et syst\u00e8me de mesure du facteur de perte<\/h3>\n<p>L&rsquo;ICMflex de Power Diagnostix offre un aper\u00e7u approfondi de l&rsquo;\u00e9tat de l&rsquo;isolation de vos \u00e9quipements HT<br \/>\nGr\u00e2ce \u00e0 sa conception unique, l&rsquo;ICMflex permet la d\u00e9tection des d\u00e9charges partielles, la localisation des d\u00e9fauts de d\u00e9charges partielles sur les c\u00e2bles et les mesures du tan delta dans un seul et m\u00eame instrument.<\/p>\n<p><a title=\"En savoir plus sur ICMflex partial discharge detector\" href=\"https:\/\/www.megger.com\/en\/products\/icmflex-partial-discharge-detector-partial-discharge-fault-locator-and-loss-factor\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">En savoir plus<\/span><\/a><\/td>\n<\/tr>\n<tr>\n<td width=\"500\">\n<div style=\"text-align: center;\">\n<p><a title=\"En savoir plus sur ICMcompact partial discharge detector\" href=\"https:\/\/www.megger.com\/en\/products\/icmcompact-standalone-partial-discharge-detector\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6644\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMCompact_PRODWEB_001.png-300x300.webp\" alt=\"ICMcompact partial discharge detector\" width=\"300\" height=\"300\" srcset=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMCompact_PRODWEB_001.png-300x300.webp 300w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMCompact_PRODWEB_001.png-150x150.webp 150w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMCompact_PRODWEB_001.png.webp 680w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\n<\/a><\/p>\n<\/div>\n<h3>ICMcompact \u2013 D\u00e9tecteur de d\u00e9charges partielles autonome<\/h3>\n<p>Un d\u00e9tecteur de d\u00e9charges partielles permettant d&rsquo;effectuer des tests de r\u00e9ception et des mesures de d\u00e9charges partielles conform\u00e9ment \u00e0 la norme CEI 60270<br \/>\nL&rsquo;ICMcompact de Power Diagnostix est un d\u00e9tecteur num\u00e9rique compact de d\u00e9charges partielles (DP) destin\u00e9 \u00e0 l&rsquo;\u00e9valuation de l&rsquo;\u00e9tat de l&rsquo;isolation moyenne et haute tension.<\/p>\n<p><a title=\"En savoir plus sur ICMcompact partial discharge detector\" href=\"https:\/\/www.megger.com\/en\/products\/icmcompact-standalone-partial-discharge-detector\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">En savoir plus<\/span><\/a><\/td>\n<td width=\"500\">\n<div style=\"text-align: center;\">\n<p><a title=\"En savoir plus sur ICMexpert partial discharge database software\" href=\"https:\/\/www.megger.com\/en\/products\/icmexpert\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6647\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMexpert_PRODWEB_001.png-300x300.webp\" alt=\"ICMexpert partial discharge database software\" width=\"300\" height=\"300\" srcset=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMexpert_PRODWEB_001.png-300x300.webp 300w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMexpert_PRODWEB_001.png-150x150.webp 150w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMexpert_PRODWEB_001.png.webp 680w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\n<\/a>\n<\/div>\n<h3>ICMexpert &#8211; Logiciel de base de donn\u00e9es<\/h3>\n<p>Logiciel de base de donn\u00e9es pour la gestion des profils de d\u00e9charges partielles (DP)<br \/>\nICMexpert \u00e9tend les possibilit\u00e9s des programmes Power Diagnostix tels que ICMcompact, ICMmonitor, ICMsystem, HVpilot, ICMflex et GISmonitor.<\/p>\n<p><a title=\"En savoir plus sur ICMexpert partial discharge database software\" href=\"https:\/\/www.megger.com\/en\/products\/icmexpert\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">En savoir plus<\/span><\/a><\/td>\n<td width=\"500\">\n<div style=\"text-align: center;\">\n<p><a title=\"En savoir plus sur ICMmonitor partial discharge monitoring system\" href=\"https:\/\/www.megger.com\/en\/products\/icmmonitor-line-partial-discharge-monitor\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6653\" src=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMmonitor_WEBI_002.png-300x300.webp\" alt=\"ICMmonitor partial discharge monitoring system\" width=\"300\" height=\"300\" srcset=\"https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMmonitor_WEBI_002.png-300x300.webp 300w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMmonitor_WEBI_002.png-150x150.webp 150w, https:\/\/control-protection.be\/wp-content\/uploads\/2026\/04\/ICMmonitor_WEBI_002.png.webp 680w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\n<\/a><\/p>\n<\/div>\n<h3>ICMmonitor \u2013 Moniteur de d\u00e9charges partielles en ligne<\/h3>\n<p>ICMmonitor prot\u00e8ge vos \u00e9quipements moyenne et haute tension en surveillant les d\u00e9charges partielles dans l&rsquo;isolation<br \/>\nICMmonitor de Power Diagnostix est un syst\u00e8me de mesure permettant la surveillance permanente en ligne des d\u00e9charges partielles (PD) sur les \u00e9quipements moyenne et haute tension.<\/p>\n<p><a title=\"En savoir plus sur ICMmonitor partial discharge monitoring system\" href=\"https:\/\/www.megger.com\/en\/products\/icmmonitor-line-partial-discharge-monitor\" target=\"_blank\" rel=\"noopener\"><span style=\"color: red; font-weight: bold;\">En savoir plus<\/span><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n        <\/div>\n    <\/div>\n<\/div><div class=\"rw-boostu-wrapper rw-whitespace\"><\/div><div class=\"rw-boostu-wrapper rw-cta \">\n    <div class=\"wpbf-container\">\n        <div class=\"cta-text\">\n            <h2>Commandez votre \u00e9quipement de mesure des d\u00e9charges partielles aupr\u00e8s de Control &#038; Protection<\/h2>\n            <div><p>Procurez-vous les outils adapt\u00e9s pour d\u00e9tecter les d\u00e9fauts \u00e0 un stade pr\u00e9coce et garantir la fiabilit\u00e9 de vos syst\u00e8mes. Control &amp; Protection fournit des \u00e9quipements de mesure des d\u00e9charges partielles de pointe de la marque Megger, accompagn\u00e9s de conseils d&rsquo;experts.<\/p>\n<\/div>\n            <p><a class=\"arrow-btn\" href=\"Contact\" target=\"_self\">Vous souhaitez parler \u00e0 notre expert ?<\/a><\/p>\n        <\/div>\n            <\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":9,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-6184","page","type-page","status-publish","hentry","wpbf-post"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Solutions de test pour d\u00e9charges partielles | Control &amp; Protection<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solutions de test pour d\u00e9charges partielles | Control &amp; Protection\" \/>\n<meta property=\"og:url\" content=\"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/\" \/>\n<meta property=\"og:site_name\" content=\"Control &amp; Protection\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-21T07:22:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/control-protection.be\/wp-content\/uploads\/2023\/01\/Megger-AVO-field-original-original.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"783\" \/>\n\t<meta property=\"og:image:height\" content=\"522\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/control-protection.be\\\/fr\\\/solutions-de-test-pour-decharges-partielles\\\/\",\"url\":\"https:\\\/\\\/control-protection.be\\\/fr\\\/solutions-de-test-pour-decharges-partielles\\\/\",\"name\":\"Solutions de test pour d\u00e9charges partielles | Control &amp; Protection\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/control-protection.be\\\/#website\"},\"datePublished\":\"2026-04-20T16:17:41+00:00\",\"dateModified\":\"2026-04-21T07:22:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/control-protection.be\\\/fr\\\/solutions-de-test-pour-decharges-partielles\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/control-protection.be\\\/fr\\\/solutions-de-test-pour-decharges-partielles\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/control-protection.be\\\/fr\\\/solutions-de-test-pour-decharges-partielles\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/control-protection.be\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solutions de test pour d\u00e9charges partielles\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/control-protection.be\\\/#website\",\"url\":\"https:\\\/\\\/control-protection.be\\\/\",\"name\":\"Control & Protection\",\"description\":\"Automation and Electrical Test Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/control-protection.be\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/control-protection.be\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/control-protection.be\\\/#organization\",\"name\":\"Control & Protection\",\"url\":\"https:\\\/\\\/control-protection.be\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/control-protection.be\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/control-protection.be\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/cp_logo.svg\",\"contentUrl\":\"https:\\\/\\\/control-protection.be\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/cp_logo.svg\",\"caption\":\"Control & Protection\"},\"image\":{\"@id\":\"https:\\\/\\\/control-protection.be\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/control-protection\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Solutions de test pour d\u00e9charges partielles | Control &amp; Protection","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/","og_locale":"fr_FR","og_type":"article","og_title":"Solutions de test pour d\u00e9charges partielles | Control &amp; Protection","og_url":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/","og_site_name":"Control &amp; Protection","article_modified_time":"2026-04-21T07:22:08+00:00","og_image":[{"width":783,"height":522,"url":"https:\/\/control-protection.be\/wp-content\/uploads\/2023\/01\/Megger-AVO-field-original-original.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/","url":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/","name":"Solutions de test pour d\u00e9charges partielles | Control &amp; Protection","isPartOf":{"@id":"https:\/\/control-protection.be\/#website"},"datePublished":"2026-04-20T16:17:41+00:00","dateModified":"2026-04-21T07:22:08+00:00","breadcrumb":{"@id":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/control-protection.be\/fr\/solutions-de-test-pour-decharges-partielles\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/control-protection.be\/fr\/"},{"@type":"ListItem","position":2,"name":"Solutions de test pour d\u00e9charges partielles"}]},{"@type":"WebSite","@id":"https:\/\/control-protection.be\/#website","url":"https:\/\/control-protection.be\/","name":"Control & Protection","description":"Automation and Electrical Test Solutions","publisher":{"@id":"https:\/\/control-protection.be\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/control-protection.be\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/control-protection.be\/#organization","name":"Control & Protection","url":"https:\/\/control-protection.be\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/control-protection.be\/#\/schema\/logo\/image\/","url":"https:\/\/control-protection.be\/wp-content\/uploads\/2022\/12\/cp_logo.svg","contentUrl":"https:\/\/control-protection.be\/wp-content\/uploads\/2022\/12\/cp_logo.svg","caption":"Control & Protection"},"image":{"@id":"https:\/\/control-protection.be\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/control-protection\/"]}]}},"_links":{"self":[{"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/pages\/6184","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/comments?post=6184"}],"version-history":[{"count":8,"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/pages\/6184\/revisions"}],"predecessor-version":[{"id":6737,"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/pages\/6184\/revisions\/6737"}],"wp:attachment":[{"href":"https:\/\/control-protection.be\/fr\/wp-json\/wp\/v2\/media?parent=6184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}